{"product_id":"itclamp50","title":"iTClamp50","description":"\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eThe iTClampTM50 quickly controls critical bleeding by closing the skin to create a temporary, contained hematoma until surgical repair. The iTClamp50 is a self-locking surgical clamp with suture needles that penetrate the skin to evert the skin edges between pressure bars of the device and anchor it to the skin to reduce slippage and leakage. Pressure is evenly distributed across the bars, which seal the skin over a wound. An adjustable locking mechanism increases or decreases pressure across the wound to achieve a fluid tight seal.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eProduct Info\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eFast: Applied in 10 seconds or less1\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eVersatile: Stops bleeding in all compressible sites\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eEffective: 100% survival in lethal groin injury model2\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch3\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eProduct attributes\u003c\/span\u003e\u003c\/h3\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eFDA-cleared to stops extremity, axillary or inguinal bleeding in seconds\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eThe only non-tourniquet hemostatic device intended for care under fire\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eOne handed application\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eSimple to adjust placement as required\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eClamp mechanism does not occlude distal perfusion as with most tourniquets\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eLight, portable and accessible\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch3\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eClinical Benefits\u003c\/span\u003e\u003c\/h3\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eApplication effectiveness:\u003c\/span\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eApplied in 10 seconds or less\u003cspan\u003e1\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003eGreater than 90% first try application success\u003c\/li\u003e\r\n\u003cli\u003eVersatile in treating many compressible treatment sites\u003c\/li\u003e\r\n\u003cli\u003eMinimal pain: Rated a 1 on a pain scale from 1- 10\u003c\/li\u003e\r\n\u003cli\u003eNo distal neurovascular impairment\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eMinimizes scene times:\u003c\/span\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eEasy application during mobile casualty evacuation (i.e. ambulance or helicopter)\u003c\/li\u003e\r\n\u003cli\u003eEliminates 3 minutes of manual pressure after wound packing\u003c\/li\u003e\r\n\u003cli\u003ePerfect adjunct for packing hemostatic gauze and can be applied over most clothing\u003c\/li\u003e\r\n\u003cli\u003eControls hemorrhage in a stable and\/or coagulopathic patient\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eCreates force multiplier effect:\u003c\/span\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eCan be applied during initial assessments in mass casualty triage\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eFrees up medic’s hands to attend to other casualties\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eCONTRAINDICATIONS FOR USE: The iTClamp50 is contraindicated where skin approximation cannot be obtained (for example, large skin defects under high tension). \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eWARNINGS: • This device is intended for temporary use only; use beyond three hours has not been studied. • Patients must be seen promptly by medical personnel for device removal and surgical wound closure. • Only use device as directed to avoid needle stick injury. • Do not use where delicate structures are near the skin surface, within 10mm, such as the orbits of the eye. • Will not control hemorrhage in non-compressible sites, such as the abdominal and chest cavities.  • Ensure personal protective equipment is utilized to protect against potential splashing of blood during application.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003ePRECAUTIONS: • Single-use, disposable device; not for reuse. Re-use of device may cause cross contamination, leading to patient risk and complication(s). • iTClampTM50 is provided sterile (sterilized by EtO). Do not use if sterility seal has been tampered with or packaging is damaged. • Not compatible with Magnetic Resonance Imaging (MRI) procedures. • Dispose of the device in accordance with local guidelines for biohazard sharps. • The device and\/or component(s) are not made from natural rubber, latex free.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eDIRECTIONS FOR USE: The iTClampTM50 controls bleeding by sealing the skin closed to create a temporary pool of blood (hematoma) under pressure. This permits formation of a stable clot until surgical repair can be obtained.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eAPPLICATION (One-handed operation): \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eHemostatic gauze can be placed inside wound before iTClamp50 application.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e1. Open the package by pulling forward on the outer tabs. \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e2. Remove the device from the package by lifting up, taking care not to close the device until it has been applied to the wound. NOTE: Device seal will hold device open until broken. \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e 3. If the device has inadvertently closed, push the side buttons inward with one hand, and pull the device open with the other hand. \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e4. Locate the wound edges . \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e5. Align the device parallel to the length of wound edge. Position the needles about 1-2 cm (0.5-1 in.) from the wound edge on either side .\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e6.Press the arms of device together to close the device. Device seal will break with pressure, allowing device to close . \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e7.Ensure the entire wound is sealed and bleeding stops. \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e 8.A gauze or compression wrap can be placed around the device on the wound to protect the device and increase pressure on the wound to limit hematoma expansion. \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eNOTE: More than one device may be required. \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eIF BLEEDING CONTINUES: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003ea. If bleeding continues while the device is in the correct position, close the device more firmly by applying further pressure to the arms of the device.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eb. If bleeding continues because the wound is too large, apply a second device to the open section. \u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003ec. If bleeding continues because the device is not positioned correctly, remove the device according to instructions and reapply.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eRequires: \u003cspan\u003ePurchase of some medical devices that may be labeled “Caution” or “RX only” requires that purchaser is a licensed physician or work under the direct supervision of a licensed physician.\u003cstrong\u003e Ensuring this supervision is the purchasers' responsibility.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Alton First Aid","offers":[{"title":"Yes","offer_id":49000713519354,"sku":"iTClamp50","price":73.99,"currency_code":"USD","in_stock":true},{"title":"No","offer_id":49000713552122,"sku":"iTClamp50","price":73.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0842\/5193\/4970\/files\/Image_200B_iTCLAMP_under_OTHER_HEMORRHAGE_CONTROL_DEVICES_canva_AALTON___23351.1633813255.1280.1280.jpg?v=1781311031","url":"https:\/\/altonfirstaid.com\/products\/itclamp50","provider":"Alton First Aid","version":"1.0","type":"link"}